S4 · Polymer seals (FFKM, PTFE, FKM)

Polymer seals fail in different ways.
Start with the duty.

FFKM, modified PTFE, NBR and FKM for oil, gas, chemicals and steam. Material options must be checked against medium, temperature, pressure, motion and groove conditions.

01Failure modes› 02What we provide› 03Material anchor›

How failure is judged

Each row identifies material data, a test or a field record to review. Rules of thumb are not a substitute for evidence.

Failure modeSymptomCriterionData source
Compression setSealing force decays or slow leakage appearsCompression-set result by temperature and timeAgeing data + thermal history
ExtrusionSeal edge enters the clearance gapGap, pressure and hardness reviewed togetherGroove dimensions + pressure rating
Chemical swellingVolume gain, softening or strength lossCompatibility at the actual concentration and temperatureMedium + concentration + temperature
Thermal ageingHardening, cracking or surface changeMaterial condition against the ageing profileCumulative heat history

Three ways we support this scenario

FFKM · Modified PTFE · NBR / FKM

Start with material form, duty limits and validation requirements — not a specification promise from a general model.

Boundary
No absolute life promise and no fictitious sample downloads

Selection results are engineering guidance only. Sample reports will be added only when genuine redacted documents are available.

Discuss the duty and validation plan →